250–4320 kW prime power · 40 set models
Medium-Speed Series Marine Diesel Generator Set
Models: CCFJ250J-W* · CCFJ300J-W* · CCFJ400J-W* · CCFJ350J-W* · CCFJ450J-W* · CCFJ500J-W* · CCFJ600J-W* · CCFJ700J-W* · +32 more in the line-up



At a glance
Supplied by an original Weichai diesel engine supplier, the Weichai Medium-Speed Marine Diesel Generator Set is.
Product Overview
Weichai marine generator sets divide by application into main generator sets and emergency generator sets, with main sets rated 16-4320 kW and emergency sets covering 30-900 kW. By fuel, main sets are divided into diesel and gas generator sets: the diesel range includes the Yangchai series, the WP4/WP6 series, the Steyr series, the Lanqing series, the Baudouin series, the 170/WH17/WH20/WH25/WH28/S3 products and the CW200/250 products; gas sets are mainly the WP4/WP6, WP13 and 6M33 products. Set manufacture and testing follow the general technical conditions of GB/T 13032-2010 for marine diesel generator sets. Please note: this line-up and description are based mainly on 50 Hz products; 60 Hz products of the corresponding ratings can also be supplied.
Model Line-up
| Series | Model | Prime power (kW) | Continuous power (kW) | Diesel engine model | Governor | Emission stage | Overall dimensions (mm) | Net weight (kg) |
|---|---|---|---|---|---|---|---|---|
| X170mechanical pump | CCFJ250J-W* | 250 | 250 | X6170ZCD280-1 | electronic-mechanical | IMO Tier Ⅱ | 3296*1376*1889 | 5200 |
| X170mechanical pump | CCFJ300J-W* | 300 | 300 | X6170ZCD330-1 | electronic-mechanical | IMO Tier Ⅱ | 3296*1376*1889 | 5200 |
| X170mechanical pump | CCFJ400J-W* | 400 | 400 | 8170ZCD441-1 | electronic-mechanical | IMO Tier Ⅱ | 3936*1380*2219 | 7050 |
| X170electronically controlled pump | CCFJ250J-W* | 250 | 250 | X6170ZCD280-1 | electronically controlled | IMO Tier Ⅱ, China marine Stage II | 3296*1376*1889 | 5200 |
| X170electronically controlled pump | CCFJ300J-W* | 300 | 300 | X6170ZCD330-1 | electronically controlled | IMO Tier Ⅱ, China marine Stage II | 3296*1376*1889 | 5200 |
| X170electronically controlled pump | CCFJ300J-W* | 300 | 300 | X6170ZCD350-2 | electronically controlled | IMO Tier Ⅱ, China marine Stage II | 3296*1376*1889 | 5200 |
| X170electronically controlled pump | CCFJ350J-W* | 350 | 350 | X6170ZCD400-1 | electronically controlled | IMO Tier Ⅱ, China marine Stage II | 3296*1376*1889 | 5200 |
| X170electronically controlled pump | CCFJ400J-W* | 400 | 350 | X6170ZCD440-1 | electronically controlled | IMO Tier Ⅱ, China marine Stage II | 3296*1376*1889 | 5200 |
| X170electronically controlled pump | CCFJ400J-W* | 400 | 350 | X6170ZCD441-2 | electronically controlled | IMO Tier Ⅱ, China marine Stage II | 3296*1376*1889 | 5200 |
| X170electronically controlled pump | CCFJ400J-W* | 400 | 400 | 8170ZCD441-1 | electronically controlled | IMO Tier Ⅱ, China marine Stage II | 3936*1380*2219 | 7050 |
| X170electronically controlled pump | CCFJ450J-W* | 450 | 450 | 8170ZCD490-1 | electronically controlled | IMO Tier Ⅱ, China marine Stage II | 3936*1380*2219 | 7050 |
| X170electronically controlled pump | CCFJ500J-W* | 500 | 500 | 8170ZCD570-1 | electronically controlled | IMO Tier Ⅱ, China marine Stage II | 3936*1380*2219 | 7050 |
| WH17 | CCFJ450J-W* | 450 | 450 | 6WH17CD539-1 | electronically controlled | IMO Tier Ⅱ, China marine Stage II | 4094*1625*2166 | 7700 |
| WH17 | CCFJ500J-W* | 500 | 500 | 6WH17CD638-2 | electronically controlled | IMO Tier Ⅱ, China marine Stage II | 4094*1625*2166 | 7700 |
| WH17 | CCFJ500J-W* | 550 | 500 | 6WH17CD638-2 | electronically controlled | IMO Tier Ⅱ, China marine Stage II | 4094*1625*2166 | 7700 |
| WH17 | CCFJ600J-W* | 600 | 500 | 6WH17CD660-5 | electronically controlled | IMO Tier Ⅱ, China marine Stage II | 4094*1625*2166 | 7700 |
| WH17 | CCFJ600J-W* | 600 | 600 | 8WH17CD770-1 | electronically controlled | IMO Tier Ⅱ, China marine Stage II | 4500*1627*2210 | 10700 |
| WH17 | CCFJ700J-W* | 700 | 700 | 8WH17CD858-2 | electronically controlled | IMO Tier Ⅱ, China marine Stage II | 4500*1627*2210 | 10700 |
| WH17 | CCFJ850J-W* | 850 | 800 | 8WH17CD1078-5 | electronically controlled | IMO Tier Ⅱ, China marine Stage II | 4500*1627*2210 | 10700 |
| WH17 | CCFJ800J-W* | 800 | 800 | 12WH17CD990-1 | electronically controlled | IMO Tier Ⅱ, China marine Stage II | 4545*1800*2371 | 12800 |
| WH17 | CCFJ1000J-W* | 1000 | 900 | 12WH17CD1210-2 | electronically controlled | IMO Tier Ⅱ, China marine Stage II | 4545*1800*2371 | 12800 |
| WH17 | CCFJ1000J-W* | 1000 | 1000 | 12WH17CD1265-5 | electronically controlled | IMO Tier Ⅱ, China marine Stage II | 4545*1800*2371 | 12800 |
| WH17 | CCFJ1200J-W* | 1200 | 1200 | 12WH17CD1485-5 | electronically controlled | IMO Tier Ⅱ, China marine Stage II | 4545*1800*2371 | 12800 |
| WH17 | CCFJ1300J-W* | 1300 | 1200 | 12WH17CD1595-5 | electronically controlled | IMO Tier Ⅱ, China marine Stage II | 4545*1800*2371 | 12800 |
| CW200 | CCFJ500J-WM* | – | 500 | CW6200ZD | mechanical-hydraulic or electronic-hydraulic | IMO Tier Ⅱ | 4700*1800*2450 | 12900 |
| CW200 | CCFJ600J-WM* | – | 600 | XCW6200ZD | mechanical-hydraulic or electronic-hydraulic | IMO Tier Ⅱ | 4700*1800*2450 | 12900 |
| CW200 | CCFJ700J-WM* | – | 700 | XCW6200ZD-10 | mechanical-hydraulic or electronic-hydraulic | IMO Tier Ⅱ | 4700*1800*2450 | 12900 |
| CW200 | CCFJ800J-WM* | – | 800 | XCW8200ZD-1 | mechanical-hydraulic or electronic-hydraulic | IMO Tier Ⅱ | 5600*2000*2500 | 15600 |
| CW200 | CCFJ900J-WM* | – | 900 | XCW8200ZD-10 | mechanical-hydraulic or electronic-hydraulic | IMO Tier Ⅱ | 5600*2000*2500 | 15600 |
| CW200 | CCFJ1200J-WM* | – | 1200 | XCW12V200ZD-1 | mechanical-hydraulic or electronic-hydraulic | IMO Tier Ⅱ | 6000*2000*3000 | 20000 |
| CW200 | CCFJ1500J-WM* | – | 1500 | CW16V200ZD | mechanical-hydraulic or electronic-hydraulic | IMO Tier Ⅱ | 6500*2000*3000 | 25000 |
| CW200 | CCFJ500J-WM* | – | 500 | CW6200ZD-358 | electronically controlled | IMO Tier Ⅱ | 4700*1800*2450 | 12900 |
| CW200 | CCFJ600J-WM* | – | 600 | CW6200ZD-363 | electronically controlled | IMO Tier Ⅱ | 4700*1800*2450 | 12900 |
| CW200 | CCFJ700J-WM* | – | 700 | CW6200ZD-369 | electronically controlled | IMO Tier Ⅱ | 4700*1800*2450 | 12900 |
| CW200 | CCFJ800J-WM* | – | 800 | CW6200ZD-373 | electronically controlled | IMO Tier Ⅱ | 4700*1800*2450 | 12900 |
| CW200 | CCFJ1000J-WM* | – | 1000 | CW8200ZD-355 | electronically controlled | IMO Tier Ⅱ | 5600*2000*2500 | 15600 |
| CW250 | CCFJ1200J-WM* | – | 1200 | CW6250ZLD | mechanical-hydraulic or electronic-hydraulic | IMO Tier Ⅱ | 6150*2000*3100 | 24150 |
| CW250 | CCFJ1700J-WM* | – | 1700 | CW8250ZLD | mechanical-hydraulic or electronic-hydraulic | IMO Tier Ⅱ | 7700*2000*3300 | 28000 |
| WH20 | CCFJ600J-WM* | – | 600 | 6WH20LCD700-7.5 | mechanical-hydraulic or electronic-hydraulic | IMO Tier ⅡChina marine Stage I | 5400*1820*2430 | 16500 |
| WH20 | CCFJ800J-WM* | – | 800 | 6WH20LCD900-7.5 | mechanical-hydraulic or electronic-hydraulic | IMO Tier ⅡChina marine Stage I | 5400*1820*2430 | 16800 |
| WH20 | CCFJ900J-WM* | – | 900 | 6WH20LCD1000-1 | mechanical-hydraulic or electronic-hydraulic | IMO Tier Ⅱ China marine Stage I | 5400*1820*2430 | 16000 |
| WH20 | CCFJ1000J-WM* | – | 1000 | 6WH20LCD1118-1 | mechanical-hydraulic or electronic-hydraulic | IMO Tier ⅡChina marine Stage I | 5600*1820*2430 | 16500 |
| WH20 | CCFJ1100J-WM* | – | 1100 | 6WH20LCD1200-1 | mechanical-hydraulic or electronic-hydraulic | IMO Tier ⅡChina marine Stage I | 5600*1820*2430 | 16500 |
| WH20 | CCFJ1100J-WM* | – | 1100 | 8WH20LCD1200-7.5 | mechanical-hydraulic or electronic-hydraulic | IMO Tier ⅡChina marine Stage I | 6350*1800*2820 | 21600 |
| WH20 | CCFJ1250J-WM* | – | 1250 | 8WH20LCD1440-1 | mechanical-hydraulic or electronic-hydraulic | IMO Tier ⅡChina marine Stage I | 6350*1800*2820 | 21300 |
| WH20 | CCFJ1400J-WM* | – | 1400 | 8WH20LCD1600-1 | mechanical-hydraulic or electronic-hydraulic | IMO Tier ⅡChina marine Stage I | 6350*1800*2830 | 21600 |
| WH20 | CCFJ600J-WM* | – | 600 | 6WH20LCD700-7.5A0 | electronically controlled ECU | IMO Tier Ⅱ, China marine Stage II | 5400*1820*2430 | 16500 |
| WH20 | CCFJ700J-WM* | – | 700 | 6WH20LCD825-7.5A0 | electronically controlled ECU | IMO Tier Ⅱ, China marine Stage II | 5400*1820*2430 | 16700 |
| WH20 | CCFJ800J-WM* | – | 800 | 6WH20LCD900-7.5A0 | electronically controlled ECU | IMO Tier Ⅱ, China marine Stage II | 5400*1820*2430 | 16800 |
| WH20 | CCFJ900J-WM* | – | 900 | 6WH20LCD1000-1A0 | electronically controlled ECU | IMO Tier Ⅱ, China marine Stage II | 5400*1820*2430 | 16000 |
| WH20 | CCFJ1000J-WM* | – | 1000 | 6WH20LCD1118-1A0 | electronically controlled ECU | IMO Tier Ⅱ, China marine Stage II | 5600*1820*2430 | 16500 |
| WH20 | CCFJ1100J-WM* | – | 1100 | 6WH20LCD1200-1A0 | electronically controlled ECU | IMO Tier Ⅱ, China marine Stage II | 5600*1820*2430 | 16500 |
| WH20 | CCFJ1100J-WM* | – | 1100 | 8WH20LCD1200-7.5A0 | electronically controlled ECU | IMO Tier Ⅱ, China marine Stage II | 6350*1800*2820 | 21600 |
| WH20 | CCFJ1250J-WM* | – | 1250 | 8WH20LCD1440-1A0 | electronically controlled ECU | IMO Tier Ⅱ, China marine Stage II | 6350*1800*2820 | 21300 |
| WH20 | CCFJ1400J-WM* | – | 1400 | 8WH20LCD1600-1A0 | electronically controlled ECU | IMO Tier Ⅱ, China marine Stage II | 6350*1800*2830 | 21600 |
| WH25 | CCFJ1100J-WM* | – | 1100 | 6WH25LCD1296-7.2 | electronic-hydraulic | IMO Tier Ⅱ/China marine Stage II | 7040*2100*3021 | 31500 |
| WH25 | CCFJ1300J-WM* | – | 1300 | 6WH25LCD1470-7.5 | electronic-hydraulic | IMO Tier Ⅱ/China marine Stage II | 7040*2100*3021 | 31500 |
| WH25 | CCFJ1600J-WM* | – | 1600 | 6WH25LCD1800-1 | electronic-hydraulic | IMO Tier Ⅱ/China marine Stage II | 7040*2100*3021 | 32500 |
| WH25 | CCFJ1600J-WM* | – | 1600 | 8WH25LCD1800-7.5 | electronic-hydraulic | IMO Tier Ⅱ/China marine Stage II | 7880*2300*3021 | 36500 |
| WH25 | CCFJ1600J-WM* | – | 1600 | 8WH25LCD1800-7.2 | electronic-hydraulic | IMO Tier Ⅱ/China marine Stage II | 7880*2300*3021 | 36500 |
| WH25 | CCFJ1800J-WM* | – | 1800 | 8WH25LCD2000-7.5 | electronic-hydraulic | IMO Tier Ⅱ/China marine Stage II | 8060*2506*3021 | 40500 |
| WH25 | CCFJ2000J-WM* | – | 2000 | 8WH25LCD2200-1 | electronic-hydraulic | IMO Tier Ⅱ/China marine Stage II | 8060*2506*3021 | 40500 |
| WH25 | CCFJ2000J-WM* | – | 2000 | 8WH25LCD2200-9 | electronic-hydraulic | IMO Tier Ⅱ/China marine Stage II | 8060*2506*3021 | 39000 |
| WH25 | CCFJ2200J-WM* | – | 2200 | 8WH25LCD2450-1 | electronic-hydraulic | IMO Tier Ⅱ/China marine Stage II | 8060*2506*3021 | 39000 |
| WH28 | CCFJ1930J-W | 1930 | 1930 | 6WH28CD2244-7.5 | electronic-hydraulic | IMO Tier Ⅱ, China marine Stage II | 9397*2126*3484 | 40000 |
| WH28 | CCFJ2120J-W | 2120 | 2120 | 6WH28CD2464-7.5 | electronic-hydraulic | IMO Tier Ⅱ, China marine Stage II | 9397*2126*3484 | 40000 |
| WH28 | CCFJ2350J-W* | 2350 | 2350 | 6WH28CD2706-7.5 | electronic-hydraulic | IMO Tier Ⅱ, China marine Stage II | 9397*2126*3484 | 40000 |
| WH28 | CCFJ2580J-W | 2580 | 2580 | 8WH28CD2992-7.5 | electronic-hydraulic | IMO Tier Ⅱ, China marine Stage II | 10278*2126*3484 | 50000 |
| WH28 | CCFJ2850J-W | 2850 | 2850 | 8WH28CD3300-7.5 | electronic-hydraulic | IMO Tier Ⅱ, China marine Stage II | 10278*2126*3484 | 50000 |
| WH28 | CCFJ3000J-W* | 3000 | 3000 | 8WH28CD3476-7.5 | electronic-hydraulic | IMO Tier Ⅱ, China marine Stage II | 10278*2126*3484 | 50000 |
| WH28 | CCFJ3150J-W* | 3150 | 3150 | 8WH28CD3608-7.5 | electronic-hydraulic | IMO Tier Ⅱ, China marine Stage II | 10278*2126*3484 | 50000 |
| S3 | CCFJ2880J-W* | 2880 | 2880 | 6WH32CD3300-7.5 | electronic-hydraulic | IMO Tier Ⅱ | 9755*2620*4622 | 75000 |
| S3 | CCFJ3840J-W* | 3840 | 3840 | 8WH32CD4400-7.5 | electronic-hydraulic | IMO Tier Ⅱ | 11035*2620*4640 | 87000 |
| S3 | CCFJ4320J-W* | 4320 | 4320 | 9WH32CD4950-7.5 | electronic-hydraulic | IMO Tier Ⅱ | 11565*2620*4640 | 91000 |
Note: (i) Power definitions. Set prime power: 1. average load factor not exceeding 70% over 24 h of operation; 2. 10% overload for 1 h in every 12 h; 3. annual operating time not exceeding 3000 h. Set continuous power: 1. unlimited annual operating time; 2. operation at a constant 100% load; 3. capable of 10% overload. (ii) Power matching requirements. 1. Vessel types with annual operating time above 3000 h or with heavy shock loads – light-tender fishing vessels, freezer vessels, dredgers and pile-driving vessels, floating cranes, sand-suction vessels, wind-turbine installation vessels and the like – must be selected on set continuous power. 2. Vessels whose main load is domestic electricity or auxiliary pumps – inland transport ships, coastal fishing boats, fast craft and the like – may be selected on set prime power. (iii) Overall dimensions and weight are for reference only; for detailed product parameters and set selection please contact us for specific coordination.
Request a Quote
Send the set model designation (for example CCFJ250J-W*), the required power, frequency (50 or 60 Hz) and your destination port.
Medium-Speed Marine Diesel Generator Set frequently asked questions
Is the Medium-Speed Marine Diesel Generator Set a genuine Weichai engine?
Yes. Units are sourced through controlled supply channels to original factory specification and are supplied with export packing and documentation.
How is the Medium-Speed Marine Diesel Generator Set shipped and how long does delivery take?
Engines are crated for export and consolidated at the port. Send your model designation, quantity and destination port for a firm quotation and lead time.